The SCMVAS (Signal Conditioning Modular Voltage Attenuator System) is an analog signal conditioning system designed to safely monitor and accurately measure voltage potentials up to 460VAC (1300V peak-to-peak). These high level voltages are typically found in industrial applications such as induction heaters or electric-motor drive controllers. The system reduces the input signal to a level suitable for interface to data acquisition systems, while at the same time providing various filter characteristics and 1500Vrms isolation.
For each channel of analog input, an attenuator module, SCMVAS-M, pre-conditions the signal which is then filtered, isolated, and converted to a high-level voltage output using an SCM5B30-07 or SCM5B40-07 module. The SCM5B40-07 module with a 10kHz bandwidth is recommended for common 50/60Hz signals low in harmonics where the user is interested in measuring only AC voltage. The SCM5B30-07 module is used for low frequency AC signals below 4Hz. The attenuator and signal conditioning modules have excellent stability over time and do not require recalibration. Overall system accuracy is ±0.06%.
Input signal connections to the SCMVAS-M attenuator module are made using a pluggable terminal block for ease of system assembly and reconfiguration. For safety purposes, the terminal block has a cover over the screws and there are no other exposed high-voltage points on the SCMVAS-M series modules, SCM5B30-07 or SCM5B40-07 module, or the mounting backpanel.
Features
- Accepts Millivoltage and Voltage Level Signals
- 10kHz Signal Bandwidth
- High Level Voltage Outputs
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240VAC Continuous
- 100dB CMR
- ±0.03% Accuracy
- ±0.01% Linearity
- ±1µV/°C Drift
- CSA Certified, FM Approved, CE and ATEX Compliant
- Random Vibration : MIL-STD 202G, Method 214A, Condition 1
- Swept Sine Vibration : MIL-STD-810G, Method 514.6, modified
- Shock : MIL-STD-810F. Method 516.5