SCM5B40V

SCM5B40-07SCM5B40-07D

VOLTAGE INPUT MODULE

SCM5B40V - 5B SCMVAS Voltage Input Module with 10kHz bandwidth

CE

CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.

RoHS

This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.

Class 1 Division 2 Certified

The National Electrical Code (NEC) defines hazardous environments as areas “where fire or explosion hazards may exist due to flammable gases, vapours, liquids, dust or particles”. When such materials are found in the atmosphere of an area, a potential for explosion exists, which could be ignited if an electrical or other source of ignition is present. As defined by the classification authorities, certified devices are suitable for installation and operation within a Class 1, Division 2 environment. Class 1 environments are areas where there is a presence of flammable gases or vapours in the air, such as natural gas or petroleum vapour. Facilities including oil rigs, refineries, gas plants and automotive repair centres all fall within this category.

CSA Approved

CSA certification indicates that a product, process or service has been tested to a Canadian or U.S. standard and it meets the requirements of an applicable CSA standard or another recognised document used as a basis for certification.

FM Approved

FM approved certification is a standard set by FM Global. Industrial and commercial companies around the world rely on products and services that are FM approved and specification tested to protect their properties from loss. The FM APPROVED mark, which is backed by scientific research and testing, advises customers that the product conforms to the highest standards.

ATEX approved

ATEX is the name commonly given to the European Directive 94/9/EC, also known as ATEX 95 or ATEX Equipment Directive. The regulation applies to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems. There are two categories of equipment 'I' for mining and 'II' for surface industries. The directive covers a large range of equipment, potentially including electrical equipment used on fixed offshore platforms, in petrochemical plants, mines, flour mills and other areas where a potentially explosive atmosphere may be present.

SCM5B40V Voltage Input Module
Featured in:Dataforth Signal Conditioning Modules5B Voltage Input Modules

Request a quote for this product

Enquiry information
Your name
Company name
Email address
Telephone

Add to quote list

Add the SCM5B40V to your quote list to send to our sales team for a quote on all your chosen products
Product
Availability
SCM5B40-07

SCM5B40V with -1V to +1V input, -5V to +5V output

SCM5B40-07D

SCM5B40V with -1V to +1V input, -10V to +10V output

Product
Availability
SCMXBE

DIN Rail Base Element without Snap Foot

29 in stock
Next day delivery i
SCMXVS

DIN Rail Connection Pins (4 required)

48 in stock
Next day delivery i
SCMPB01

16 Channel 5B Backpanel, Non-Multiplexed with CJC

SCMPB01-1

16 Channel 5B Backpanel, Non-Multiplexed with no CJC

SCMPB01-2

16 Channel 5B Backpanel, Non-Multiplexed with DIN rail mount, CJC

SCMPB01-3

16 Channel 5B Backpanel, Non-Multiplexed with DIN rail mount, no CJC

SCMPB02

16 Channel 5B Backpanel, Multiplexed with CJC

SCMPB02-1

16 Channel 5B Backpanel, Multiplexed with no CJC

SCMPB02-2

16 Channel 5B Backpanel, Multiplexed with DIN rail mount, CJC

SCMPB02-3

16 Channel 5B Backpanel, Multiplexed with DIN rail mount, no CJC

SCMPB03

Single Channel 5B Backpanel with CJC

SCMPB03-2

Single Channel 5B Backpanel with DIN rail mount, CJC

SCMPB04

Dual Channel 5B Backpanel with CJC

SCMPB04-1

Dual Channel 5B Backpanel with no CJC

SCMPB04-2

Dual Channel 5B Backpanel with DIN rail mount, CJC

SCMPB04-3

Dual Channel 5B Backpanel with DIN rail mount, no CJC

SCMPB05

8 Channel 5B Backpanel, Non-Multiplexed with CJC

SCMPB05-1

8 Channel 5B Backpanel, Non-Multiplexed with no CJC

SCMPB05-2

8 Channel 5B Backpanel, Non-Multiplexed with DIN rail mount, CJC

SCMPB05-3

8 Channel 5B Backpanel, Non-Multiplexed with DIN rail mount, no CJC

SCMPB06

8 Channel 5B Backpanel, Multiplexed with CJC

SCMPB06-1

8 Channel 5B Backpanel, Multiplexed with no CJC

SCMPB06-2

8 Channel 5B Backpanel, Multiplexed with DIN rail mount, CJC

SCMPB06-3

8 Channel 5B Backpanel, Multiplexed with DIN rail mount, no CJC

SCMPB07

8 Channel 5B Backpanel, High Density with CJC

SCMPB07-1

8 Channel 5B Backpanel, High Density with no CJC

SCMPB07-2

8 Channel 5B Backpanel, High Density with DIN rail mount, CJC

SCMPB07-3

8 Channel 5B Backpanel, High Density with DIN rail mount, no CJC

SCMXBEFE

DIN Rail Base Element with Snap Foot

SCMXCJC

SCM5B Encapsulated Cold Junction Compensation Sensor (MOQ 50pcs)

SCMXEV

Analog Module Evaluation Board

SCMXFS-003

4A Fuse for SCMPB01/02 Backplane, Pack of 10

SCMXIF

Universal Interface Board for SCM5B/7B Backpanels with no DIN rail mount

SCMXIF-DIN

Universal Interface Board for SCM5B/7B Backpanels with DIN rail mount

SCMXJP-003

Jumper Strap for SCMPB01 Backplane, Pack of 10

SCMXPRE-001

220V AC Power Supply (1A @ 5V DC) with no DIN rail mount

SCMXPRE-001D

220V AC Power Supply (1A @ 5V DC) with DIN rail mount

SCMXPRE-003

220V AC Power Supply (6A @ 5V DC)

SCMXPRT-001

110V AC Power Supply (1A @ 5V DC) with no DIN rail mount

SCMXPRT-001D

110V AC Power Supply (1A @ 5V DC) with DIN rail mount

SCMXPRT-003

110V AC Power Supply (6A @ 5V DC)

SCMXR1

Current Conversion Resistor for SCM5B32/42 Module

SCMXRAIL1-02

EN50022-35 Gull Wing DIN Rail, Length 2M

SCMXRAIL2-02

EN50035-G32 G Style DIN Rail, Length 2M

SCMXRAIL3-02

EN50022-35x15 Gull Wing DIN Rail, Length 2M

SCMXRK-002

19'' Metal Mounting Rack for SCM5B/7B or 8B Backplanes

SCMXSE

DIN Rail Side Element (2 required)

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)
Industry insight.
Network know-how.
Impulse engineers and specialists have the industry insight and network know-how to design forward looking solutions for wide-ranging environments.
Discover our Industrial IoT capabilities

SCM5B40V overview

Description
Downloads

The SCMVAS (Signal Conditioning Modular Voltage Attenuator System) is an analog signal conditioning system designed to safely monitor and accurately measure voltage potentials up to 460VAC (1300V peak-to-peak). These high level voltages are typically found in industrial applications such as induction heaters or electric-motor drive controllers. The system reduces the input signal to a level suitable for interface to data acquisition systems, while at the same time providing various filter characteristics and 1500Vrms isolation.

For each channel of analog input, an attenuator module, SCMVAS-M, pre-conditions the signal which is then filtered, isolated, and converted to a high-level voltage output using an SCM5B30-07 or SCM5B40-07 module. The SCM5B40-07 module with a 10kHz bandwidth is recommended for common 50/60Hz signals low in harmonics where the user is interested in measuring only AC voltage. The SCM5B30-07 module is used for low frequency AC signals below 4Hz. The attenuator and signal conditioning modules have excellent stability over time and do not require recalibration. Overall system accuracy is ±0.06%.

Input signal connections to the SCMVAS-M attenuator module are made using a pluggable terminal block for ease of system assembly and reconfiguration. For safety purposes, the terminal block has a cover over the screws and there are no other exposed high-voltage points on the SCMVAS-M series modules, SCM5B30-07 or SCM5B40-07 module, or the mounting backpanel.

Features
  • Accepts Millivoltage and Voltage Level Signals
  • 10kHz Signal Bandwidth
  • High Level Voltage Outputs
  • 1500Vrms Transformer Isolation
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240VAC Continuous
  • 100dB CMR
  • ±0.03% Accuracy
  • ±0.01% Linearity
  • ±1µV/°C Drift
  • CSA Certified, FM Approved, CE and ATEX Compliant
  • Random Vibration : MIL-STD 202G, Method 214A, Condition 1
  • Swept Sine Vibration : MIL-STD-810G, Method 514.6, modified
  • Shock : MIL-STD-810F. Method 516.5