SCM7B37

THERMOCOUPLE INPUT MODULE

SCM7B37 - 7B Thermocouple Input Module with 3Hz bandwidth

CE

CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.

RoHS

This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.

Class 1 Division 2 Certified

The National Electrical Code (NEC) defines hazardous environments as areas “where fire or explosion hazards may exist due to flammable gases, vapours, liquids, dust or particles”. When such materials are found in the atmosphere of an area, a potential for explosion exists, which could be ignited if an electrical or other source of ignition is present. As defined by the classification authorities, certified devices are suitable for installation and operation within a Class 1, Division 2 environment. Class 1 environments are areas where there is a presence of flammable gases or vapours in the air, such as natural gas or petroleum vapour. Facilities including oil rigs, refineries, gas plants and automotive repair centres all fall within this category.

CSA Approved

CSA certification indicates that a product, process or service has been tested to a Canadian or U.S. standard and it meets the requirements of an applicable CSA standard or another recognised document used as a basis for certification.

FM Approved

FM approved certification is a standard set by FM Global. Industrial and commercial companies around the world rely on products and services that are FM approved and specification tested to protect their properties from loss. The FM APPROVED mark, which is backed by scientific research and testing, advises customers that the product conforms to the highest standards.

ATEX approved

ATEX is the name commonly given to the European Directive 94/9/EC, also known as ATEX 95 or ATEX Equipment Directive. The regulation applies to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems. There are two categories of equipment 'I' for mining and 'II' for surface industries. The directive covers a large range of equipment, potentially including electrical equipment used on fixed offshore platforms, in petrochemical plants, mines, flour mills and other areas where a potentially explosive atmosphere may be present.

SCM7B37 Thermocouple Input Module
Featured in:Dataforth Signal Conditioning Modules

Request a quote for this product

Enquiry information
Your name
Company name
Email address
Telephone

Add to quote list

Add the SCM7B37 to your quote list to send to our sales team for a quote on all your chosen products
Product
Availability
SCM7B37B-07

SCM7B37 with Type B, 0 to 1800C input, +1V to +5V output

SCM7B37J-01D

SCM7B37 with Type J, -100C to 760C input, 0 to +10V output

SCM7B37J-10

SCM7B37 with Type J, 0 to 200C input, +1V to +5V output

SCM7B37J-10A

SCM7B37 with Type J, 0 to 200C input, 0 to +5V output

SCM7B37J-10D

SCM7B37 with Type J, 0 to 200C input, 0 to +10V output

SCM7B37J-11

SCM7B37 with Type J, 0 to 400C input, +1V to +5V output

SCM7B37J-11A

SCM7B37 with Type J, 0 to 400C input, 0 to +5V output

SCM7B37J-11D

SCM7B37 with Type J, 0 to 400C input, 0 to +10V output

SCM7B37J-12

SCM7B37 with Type J, 0 to 600C input, +1V to +5V output

SCM7B37J-12A

SCM7B37 with Type J, 0 to 600C input, 0 to +5V output

SCM7B37J-12D

SCM7B37 with Type J, 0 to 600C input, 0 to +10V output

SCM7B37J-13

SCM7B37 with Type J, 300C to 600C input, +1V to +5V output

SCM7B37J-13A

SCM7B37 with Type J, 300C to 600C input, 0 to +5V output

SCM7B37J-13D

SCM7B37 with Type J, 300C to 600C input, 0 to +10V output

SCM7B37K-02

SCM7B37 with Type K, -100C to 1350C input, +1V to +5V output

SCM7B37K-02A

SCM7B37 with Type K, -100C to 1350C input, 0 to +5V output

SCM7B37K-02D

SCM7B37 with Type K, -100C to 1350C input, 0 to +10V output

SCM7B37K-20

SCM7B37 with Type K, 0 to 300C input, +1V to +5V output

SCM7B37K-20A

SCM7B37 with Type K, 0 to 300C input, 0 to +5V output

SCM7B37K-20D

SCM7B37 with Type K, 0 to 300C input, 0 to +10V output

SCM7B37K-21

SCM7B37 with Type K, 0 to 600C input, +1V to +5V output

SCM7B37K-21A

SCM7B37 with Type K, 0 to 600C input, 0 to +5V output

SCM7B37K-21D

SCM7B37 with Type K, 0 to 600C input, 0 to +10V output

SCM7B37K-22

SCM7B37 with Type K, 0 to 1200C input, +1V to +5V output

SCM7B37K-22A

SCM7B37 with Type K, 0 to 1200C input, 0 to +5V output

SCM7B37K-22D

SCM7B37 with Type K, 0 to 1200C input, 0 to +10V output

SCM7B37K-23

SCM7B37 with Type K, 600C to 1200C input, +1V to +5V output

SCM7B37K-23A

SCM7B37 with Type K, 600C to 1200C input, 0 to +5V output

SCM7B37K-23D

SCM7B37 with Type K, 600C to 1200C input, 0 to +10V output

SCM7B37R-05

SCM7B37 with Type R, 0 to 1750C input, +1V to +5V output

SCM7B37R-05A

SCM7B37 with Type R, 0 to 1750C input, 0 to +5V output

SCM7B37R-05D

SCM7B37 with Type R, 0 to 1750C input, 0 to +10V output

SCM7B37S-06

SCM7B37 with Type S, 0 to 1750C input, +1V to +5V output

SCM7B37S-06A

SCM7B37 with Type S, 0 to 1750C input, 0 to +5V output

SCM7B37S-06D

SCM7B37 with Type S, 0 to 1750C input, 0 to +10V output

SCM7B37T-03

SCM7B37 with Type T, -100C to 400C input, +1V to +5V output

SCM7B37T-03A

SCM7B37 with Type T, -100C to 400C input, 0 to +5V output

SCM7B37T-03D

SCM7B37 with Type T, -100C to 400C input, 0 to +10V output

SCM7B37B-07A

SCM7B37 with Type B, 0 to 1800C input, 0 to +5V output

SCM7B37B-07D

SCM7B37 with Type B, 0 to 1800C input, 0 to +10V output

SCM7B37E-04

SCM7B37 with Type E, 0 to 900C input, +1V to +5V output

SCM7B37E-04A

SCM7B37 with Type E, 0 to 900C input, 0 to +5V output

SCM7B37E-04D

SCM7B37 with Type E, 0 to 900C input, 0 to +10V output

SCM7B37J-01

SCM7B37 with Type J, -100C to 760C input, +1V to +5V output

SCM7B37J-01A

SCM7B37 with Type J, -100C to 760C input, 0 to +5V output

Product
Availability
SCMXBE

DIN Rail Base Element without Snap Foot

29 in stock
Next day delivery i
SCMXVS

DIN Rail Connection Pins (4 required)

48 in stock
Next day delivery i
PWR-PS5R7W

DIN Rail Switching Power Supplies with 7.5W 24V DC power

SCM7BP01

7B Single Channel Backpanel with CJC

SCM7BP01-DIN

7B Single Channel Backpanel with DIN rail mount, CJC

SCM7BP02

7B Dual Channel Backpanel with CJC

SCM7BP02-DIN

7B Dual Channel Backpanel with DIN rail mount, CJC

SCM7BP04

7B 4 Channel Backpanel with CJC

SCM7BP04-DIN

7B 4 Channel Backpanel with DIN rail mount, CJC

SCM7BP08

7B 8 Channel Backpanel with CJC

SCM7BP16

7B 16 Channel Backpanel with CJC

SCM7BP16-DIN

7B 16 Channel Backpanel with DIN rail mount, CJC

SCM7BPT

Non-Isolated Pass Thru Module

SCM7BXCA01

6'' Adapter Cable for SCM7B Backpanels

SCM7BXCA02

3' Interface Cable for SCM7B Backpanels

SCM7BXEV

Analog Module Evaluation Board

SCM7BXR1

Current Conversion Resistor

SCMXBEFE

DIN Rail Base Element with Snap Foot

SCMXCA006-01

Interface Cable for 8B Backplanes with 1M length

SCMXCA006-02

Interface Cable for 8B Backplanes with 2M length

SCMXCA006-07

Interface Cable for 8B Backplanes with 7M length

SCMXIF

Universal Interface Board for SCM5B/7B Backpanels with no DIN rail mount

SCMXIF-DIN

Universal Interface Board for SCM5B/7B Backpanels with DIN rail mount

SCMXRAIL1-02

EN50022-35 Gull Wing DIN Rail, Length 2M

SCMXRAIL2-02

EN50035-G32 G Style DIN Rail, Length 2M

SCMXRAIL3-02

EN50022-35x15 Gull Wing DIN Rail, Length 2M

SCMXRK-002

19'' Metal Mounting Rack for SCM5B/7B or 8B Backplanes

SCMXSE

DIN Rail Side Element (2 required)

PWR-PS5R15W

DIN Rail Switching Power Supplies with 15W 24V DC power

PWR-PS5R30W

DIN Rail Switching Power Supplies with 30W 24V DC power

PWR-PS5R60W

DIN Rail Switching Power Supplies with 60W 24V DC power

PWR-PS5R120W

DIN Rail Switching Power Supplies with 120W 24V DC power

SCM7BP08-DIN

7B 8 Channel Backpanel with DIN rail mount, CJC

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)
Industry insight.
Network know-how.
Impulse engineers and specialists have the industry insight and network know-how to design forward looking solutions for wide-ranging environments.
Discover our Industrial IoT capabilities

SCM7B37 overview

Description
Downloads

SCM7B37 modules accept a single channel of input from Type J, K, T, E, R, S, or B thermocouples. The signal is filtered, isolated, amplified, and converted to a high level analog voltage for output to the process control system.

Features
  • Interfaces to Type J, K, T, E, R, S, and B Thermocouples
  • 3Hz Signal Bandwidth
  • Provides High Level Voltage Outputs
  • 1500Vrms Transformer Isolation
  • Accuracy, ±0.03% of Span Typical, ±0.1% Max
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 120Vrms Continuous
  • Noise, 500µV Peak (5MHz), 250µV RMS (100kHz)
  • CMRR, 160dB
  • NMR, up to 85dB
  • Easy DIN Rail Mounting
  • CSA C/US Certified
  • CE and ATEX Compliant
Enquire about the SCM7B37
Need more info or project pricing for the SCM7B37?
T: +44 (0)1782 337 800 • E: sales@impulse-embedded.co.uk

Similar products to the SCM7B37

+44(0)1782 337 800
Happy Holidays from Impulse! Please note that we will be closed for the holiday period from 20th December, and will reopen on 2nd January. Our last shipping date of the year to customers will be 18th December 2024.
+44(0)1782 337 800